Renogy Rover Lite 60A MPPT Solar Charge Controller 12V–48V
Renogy Rover Lite 60A MPPT Solar Charge Controller 12V–48V
Couldn't load pickup availability
The Renogy Rover Lite is a 60A MPPT solar charge controller compatible with 12V, 24V, 36V, and 48V battery systems, accepting up to 150V DC open-circuit solar input and delivering greater than 99% MPPT tracking efficiency and greater than 97% conversion efficiency. It supports AGM, Gel, Flooded, Lithium Iron Phosphate, and user-custom battery presets, making it a single controller for a wide range of off-grid builds: overlanding rigs, RVs, marine installations, and cabin systems. Two variants are available: Controller Only and a bundle that includes the BT-2 Bluetooth module for wireless monitoring.
Internal Potting for Reliable Heat Management
The Rover Lite uses internal potting to transfer heat from its electronics to external metal heat sinks rather than relying on airflow alone. In a truck camper shell, a van build, or a trailer compartment where ventilation is limited, a controller that runs hot throttles output or fails prematurely. The potted design keeps operating temperatures in check across the controller's rated range, so charging performance stays consistent even during sustained high-current sessions on warm days.
Low Self-Consumption Keeps More Power in Your Batteries
The Rover Lite draws just 0.18W from a 12V battery bank when the system is idle. In off-grid builds where the controller runs continuously, every watt the controller consumes for itself is a watt unavailable to run lights, a refrigerator, or a CPAP overnight. Lower standby draw is especially relevant for weekend overlanders who leave a rig parked mid-week and need the battery bank to hold charge between trips.
Low-Temperature Protection for Lithium Batteries
The Rover Lite includes low-temperature protection that suspends charging below 32°F, preventing damage to lithium iron phosphate cells during cold-weather operation. For overlanders and campers who run LiFePO4 batteries in climates where overnight temperatures drop below freezing, this protection removes the need for a separate low-temp cutoff device. The controller also applies temperature compensation for non-lithium chemistries using a -3 mV/°C/2V coefficient via the included battery temperature sensor.
Features
- 150V DC max solar input: accepts series, parallel, or series-parallel panel configurations up to 150V open-circuit voltage
- Auto system voltage recognition: detects 12V, 24V, 36V, or 48V battery banks automatically (non-lithium); lithium requires manual selection
- Multiple battery presets: AGM, Gel, Flooded, Lithium Iron Phosphate, and User Custom charging profiles
- RS485 communication port: enables integration with compatible monitoring systems
- 20A load output terminal: supports direct connection of 12V DC loads up to 20A
- LCD display with built-in buttons: shows real-time charging data without requiring an app or external device
Specifications
| Specification | Value |
|---|---|
| Rated Charge Current | 60A |
| System Voltage (Non-Lithium) | 12 / 24 / 36 / 48 VDC (Auto Recognition) |
| Battery Input Voltage Range | 9–64 VDC |
| Max Solar Input Voltage (Voc) | 150 VDC |
| Max Solar Input Power | 900W (12V) / 1800W (24V) / 2000W (36V) / 3200W (48V) |
| MPPT Tracking Efficiency | >99% |
| Conversion Efficiency | >97% |
| Self-Consumption | 0.18W (12V system) |
| Power Consumption | <15 mA (12V) / <11 mA (24V) / <8 mA (36V) / <7 mA (48V) |
| Load Output | 20A max, 12V DC |
| Battery Presets | AGM, Gel, Flooded, Lithium Iron Phosphate, User Custom |
| Charger Algorithm (Lead Acid) | 3-stage: Bulk, Boost, Float, Equalize |
| Charger Algorithm (Lithium) | 2-stage: Bulk, Boost |
| Temperature Compensation | -3 mV/°C/2V (Non-Lithium); 0 mV/°C/2V (Lithium) |
| Communication | RS485 |
| Grounding | Common Negative |
| Operating Temperature | -31°F to 113°F / -35°C to 65°C |
| Storage Temperature | -40°F to 176°F / -40°C to 80°C |
| Humidity | 0%–95% RH |
| Enclosure Rating | IP32 |
| Cooling | Heat Sink |
| Dimensions (L x W x H) | 305 x 205 x 99 mm / 12.01 x 8.07 x 3.90 in |
| Weight | 3.5 kg / 7.71 lb |
| Certifications | FCC Part 15 Class B, CE, RoHS |
| Included | Charge controller, battery temperature sensor, mounting screws (x4), user manual |
| Bluetooth Module (W/ BT Variant) | BT-2 module included; stores up to 2 years of system data |
Who This Is For and Isn't
The Rover Lite 60A is suited for off-grid builds where the battery bank is 12V, 24V, 36V, or 48V and the solar array stays within 150V open-circuit voltage: overlanding trucks and trailers, RVs, marine vessels, and cabin or workshop installations running AGM, Gel, Flooded, or LiFePO4 batteries. The W/ Bluetooth Module variant adds wireless monitoring and two-year data logging for builders who want remote visibility into system performance.
The Rover Lite is rated IP32 and is not suitable for direct exposure to rain, spray, or dusty environments without additional enclosure protection. The load output terminal supports 12V DC loads only, up to 20A. AC loads require a separate inverter connected directly to the battery bank, not to the load terminals. The Rover Lite 60A does not support auto-recognition for 36V or 48V lithium battery systems; system voltage must be set manually for lithium chemistries.
Common Questions
What solar panel configurations does the Rover Lite 60A support?
The Rover Lite 60A MPPT solar charge controller accepts series, parallel, or series-parallel panel wiring, as long as the combined open-circuit voltage does not exceed 150V DC and the array power stays within the rated maximum for the battery voltage in use: 900W at 12V, 1800W at 24V, 2000W at 36V, or 3200W at 48V.
Which battery chemistries are compatible?
The Rover Lite 60A charge controller includes presets for AGM, Gel, Flooded lead-acid, and Lithium Iron Phosphate batteries, plus a User Custom profile for non-standard charging parameters. Temperature compensation is applied automatically for non-lithium chemistries using the included battery temperature sensor; lithium presets use no temperature compensation.
Can I connect DC appliances directly to the controller?
The Rover Lite 60A includes a load output terminal rated for 12V DC loads up to 20A. AC appliances require a separate inverter wired directly to the battery bank. The load terminal is not intended for inverter connection, and the battery bank must always remain connected to the controller when the load terminal is in use.
Does the Bluetooth variant require a separate app or device?
The W/ Bluetooth Module variant includes the BT-2 module, which enables wireless monitoring and stores up to two years of system data. The Controller Only variant has an onboard LCD display and built-in buttons for real-time monitoring without Bluetooth; the BT-2 module can be added separately if needed later.
What is the operating temperature range?
The Rover Lite 60A MPPT solar charge controller is rated for operation from -31°F to 113°F (-35°C to 65°C) and includes low-temperature protection that suspends charging below 32°F to protect lithium batteries from cold-weather damage. Storage is rated from -40°F to 176°F (-40°C to 80°C).